SEPCo. supply various kinds of charge controller with good quality and competitive price.
 PWM and MPPT Charge Controllers
LCD DISPLAY , DIGITAL , LIGHT CONTROLLERS

Rated power: 100W,300W, 600W, 1500W, 2000W, 3000W    
Rated voltage: 12V, 24V, 48V

1, Over charged protection;
                      2. Over discharged protection                       .
3. Reverse polarity connection protection.
4. PV Panel reverse current protection.
5. Short circuit protection.
6. Thunder and Lighting protection

Why a Charge Controller is necessary
TriStar brand charge controller

Modern multi-stage charge controllers
Most quality charge controller units have what is known as a 3 stage charge cycle that goes like this :

1)BULK: During the Bulk phase of the charge cycle, the voltage gradually rises to the Bulk level (usually 14.4 to 14.6 volts) while the batteries draw maximum current. When Bulk level voltage is reached the absorption stage begins.

2) ABSORPTION :  During this phase the voltage is maintained at Bulk voltage level for a specified time (usually an hour) while the current gradually tapers off as the batteries charge up.

3) FLOAT :  After the absorption time passes the voltage is lowered to float level (usually 13.4 to 13.7 volts) and the batteries draw a small maintenance current until the next cycle.

The relationship between the current and the voltage during the 3 phases of the charge cycle can be shown visually by the graph below.

This chart shows the three charging stages: Bulk, Absorption, and Float

MPPT Maximum Power Point Tracking
Most multi-stage charge controllers are Pulse Width Modulation (PWM) types. I would recommend using one of at least this design. The newer Maximum Power Point Tracking (MPPT) controllers are even better. They match the output of the solar panels to the battery voltage to insure maximum charge (amps). For example: even though your solar panel is rated at 100 watts, you won't get the full 100 watts unless the battery is at optimum voltage. The Power/Watts is always equal to Volts times Amps or P=E*I). With a regular charge controller, if your batteries are low at say 12.4 volts, then your 100 watt solar panel rated at 6 amps at 16.5 volts (6 amps times 16.5 volts = 100 watts) will only charge at 6 amps times 12.4 volts or just 75 watts. You just lost 25% of your capacity! The MPPT controller compensates for the lower battery voltage by delivering closer to 8 amps into the 12.4 volt battery maintaining the full power of the 100 watt solar panel! 100 watts = 12.4 volts times 8 amps = 100 (P=E*I).

The Charge Controller is installed between the Solar Panel array and the Batteries where it automatically maintains the charge on the batteries using the 3 stage charge cycle just described. 


























 